Sauna Lumi

Sauna Planner: heater size, circuit and cost to run

Works for a room you're building or a sauna you're comparing. Everything runs in your browser; nothing is sent unless you ask for a quote.

Room (inside)
Power
Session assumptions
The thermostat cycles the heater once the room is hot; 50% is our default. Change it if your heater's manual or meter says otherwise.
6 kW 6′ inside 7′
Room volume
—
Size heater for
—
Heater
—
Running current
—
Breaker · est.
—
Copper wire · est.
—
Per session
—
Per month
—

Heaters that cover this room

Saunas close to this size

How the planner works

  1. Volume. Width × depth × height of the inside, in cubic feet. Barrels use π × radius² × length.
  2. Heater size. Makers publish a room-volume range for each heater. We add 3.94 cu ft per sq ft of glass, stone, brick or concrete and multiply solid log walls by 1.5 (Harvia's published rule: 1.2 m³ per m²; HUUM and Saunum use slightly less), then list the heaters whose published range covers the result. With no match we estimate Harvia's average of 1 kW per m³ (about 35 cu ft).
  3. Circuit. Running current = watts ÷ volts. A sauna heater is a continuous load, so the breaker is at least 125% of that, rounded up to a standard size; wire is the smallest copper gauge in NEC Table 310.16's 60 °C column rated for that breaker. Your heater's installation manual and a licensed electrician have the final say.
  4. Cost. kWh = kW × preheat hours + kW × duty × session hours, times your state's average residential price from the U.S. EIA (August 2026, Table 5.6.A).
Heater—Breaker—Per session—

Request a quote with this plan

We reply by email with the delivered price, lead time and the maker's terms. No account, no spam.